VUTLAN VT855G

Large model for Data Centers, with backup power input and the most Dry Contact inputs in the range

Dry Contact input 32 ports

Connection ports

Port typeBuilt-in quantity
Analog port (RJ12)8
Dry Contact input32
Dry Contact output8
Relay 12V 0.25A2
Relay NC/NO/COM2
CAN bus devices24
2 ports CAN รวมสูงสุด 24 Equipment (ค่าRecommended) Recommendedให้มี CAN-12V-1A เมื่อเกิน 5 Equipment

Alert channels

EmailSupport
LINE OASupport
Sends an HTTP request to the MT Notify service, limited to 300 messages/month
TelegramSupport
Built-in Telegram support, or via the MT Notify service (web service)
SMSAdd-on equipment required
An LTE Modem (sold separately) must be added in the unit's slot, with a SIM card

Spec summary

Analog port
8 ports (RJ12 auto-sensing), expandable via CAN
Dry Contact input
32 ports
Dry Contact output
8 ports (isolated, 24VDC / 15mA)
CAN bus
2 ports รวมสูงสุด 24 Equipment Recommendedให้มี CAN-12V-1A เมื่อเกิน 5 Equipment
Relay output
2 latching channels 240V 10A (NC/NO/COM) and 2 channels 12V 0.25A
Ethernet
10/100/1000 Mbps
LTE modem
LTE Modem (4G) slot (sold separately, uses a SIM); Gateway / Access / SMS modes
Extension slot
1 slot for either a VT485m or a VT485r
Backup battery
VT-ACCU slot (sold separately); supports AC/DC backup power
System limits
Up to 150 sensors/Dry Contacts/Relays in total, and up to 1,000 elements

Protocols

  • SNMP v1, v2c, v3 (and SNMP Get as a virtual sensor)
  • Modbus TCP/IP
  • Modbus RTU (RS-485) with the VT485m module
  • HTTP/HTTPS, SMTP, Syslog, FTP, RADIUS, OpenVPN

Compatible add-on modules

  • VT408 Analog sensor extension unit Analog port (RJ12) +8
    Adds 8 Analog ports per unit, connected via CAN bus
  • VT408D Sensor extension unit (DIN) Analog port (RJ12) +8
    The DIN-rail version of the VT408 adds 8 Analog ports per unit
  • VT440 Dry contacts unit Dry Contact input +32
    Adds 32 Dry Contact inputs per unit, connected via CAN bus
  • VT440 + VT32 Dry contacts unit Dry Contact input +64
    Adds 64 Dry Contact inputs per unit (the VT32 is an add-on board in the VT440)
  • VT485m Modbus RTU (RS-485) module
    Installs in the unit's Extension slot; supports up to 32 Modbus RTU devices with up to 1,000 m of cable. It uses the same slot as the VT485m ISO and VT485r, so they cannot be used together.
  • VT485m ISO Modbus RTU (RS-485) module
    The ISO Modbus RTU module uses the same Extension slot as the VT485m and cannot be used together with it. This model is not found on the manufacturer's VT335G / VT825G / VT855G product pages. Confirm the spec and compatibility with the manufacturer.
  • LTE Modem
    Sold separately. Installs in the slot inside the unit and takes a SIM card (not a USB modem). The module model/part number depends on the controller model.
  • VT-BAT / VT-ACCU battery extension
    Backup battery for models with a battery compartment
Information to confirm with the manufacturer before quoting
  • The elements value differs within the product page (1,000 and 1,500)
  • VT485m ISO does not appear on the product page

Sources